For a social bathhouse: saunas in the courtyard, the deep pool as the plunge, the hall as lounge and changing rooms.

Sauna and cold-plunge bathhouse. District CMUO.
A venue run under Health Code Article 47 is a different use, and conditional.
By right: allowed without a hearing. By permit: needs the permit named.
Layout Click a room to see its measurements
Dimensions are from the survey model. Verify on site.
Tinted on the plan.
| No. | Room | Used as | Area |
|---|---|---|---|
| G10 | Pool courtyardSaunas, outdoor bathing | Saunas, outdoor bathing | 1,228 SF (114.1 m²) |
| G11 | PoolPlungeBasin not surveyed | Plunge | 479 SF (44.5 m²) |
| G14 | Covered garageSauna roomsOutline assumed | Sauna rooms | 492 SF (45.7 m²) |
| G01 | Main hall, frontReception, lockers | Reception, lockers | 502 SF (46.6 m²) |
| G02 | Main hall, tall partShowers, lounge | Showers, lounge | 524 SF (48.7 m²) |
| U01 | Front officeQuiet rooms | Quiet rooms | 407 SF (37.8 m²) |
| L01 | Loft officeQuiet rooms | Quiet rooms | 141 SF (13.1 m²) |
The written answer on how a business that uses the open-air pool is classified. No duration is published for this letter. Source
For the fit-out and any change of use. The city: “All tenant improvements require building permits.” Source
A new operator applies in its own name. Plans and a Pool/Spa Data Sheet go to the department if anything is built, remodelled or the equipment is changed. Source
A pool under 300 linear feet of wall needs one accessible entry, “either a pool lift or a sloped entry”; for an existing pool, “to the extent that it is readily achievable”. Source
Building work triggers an accessible path of travel to the altered area: entrance, toilets, signs. Below the state valuation threshold the spend is capped at 20% of the adjusted construction cost. Source
With Fire Department plan review, if the space is set up for 50 or more people. Source
Not law. The bill would bring cold spas under public pool law. It was held in committee on 14 May 2026. Source
For sauna heaters, new showers and drains.
Massage is permitted on the ground floor with this permit. On the 2nd floor it also needs a Conditional Use authorization. Source
Before any work on the pool shell, deck, enclosure, plumbing, filtration or heater.
For installing or replacing a pool heater. Source
Under 50 occupants an assembly use is classed as business (Group B). At 50 or more it becomes Group A, which changes the exiting and fire protection requirements.
Fire permits are not transferable. Any change of operator or use needs a new permit. Source
For candles or open flame where people gather. Fee $446.00. Source
For installing or changing a business sign or awning. Painted or vinyl lettering applied directly to windows, doors or the facade is exempt. Source
Ask the SFPUC before the pool is emptied whether this permit applies. Source
Before signing: the Certificate of Final Completion and Occupancy, older permits and job cards that are not online. $0.10 per page; up to 15 days. Source
Cost band: high.
Sauna rooms, showers, lockers, drainage, ventilation, water heating, and a pool brought up to public standard: plumbing and mechanical work throughout.
Time band: 3 to 6 months.
No zoning hearing for a personal-service bathhouse. Plan review by Building, Fire and Health for the wet rooms and the pool, then construction.
What to check for this use before committing.
Personal service is by right, and the code's definition names health spas, bathhouses and steam rooms. Use of the open-air pool needs a Zoning Administrator letter and a Health Department permit. Massage on the 2nd floor needs a Conditional Use authorization.